In the following example X-Ray inspection was performed on an Agilet HCPL3101 (Datasheet and Photo of HCPL3101). Evidence of the Die and Wire Bonding is evident in the center of the X-Ray Image. Wire Bonding from the Die to the Pins is also evident and the non-connect pins are consistant with the MFG datasheet.
X-Ray Image of HCPL3101 |
The second example of X-Ray inspection was performed on a MC14163BCL (Datasheet and Photos). As this part is a Ceramic DIL package the beam power required to penetrate the ceramic body causes much of the inside of the component to be "washed out." Very sophisticated and very expensive equiptment is required to be able to identify the Die Frame, Die, and Wire Bonding in the same image during X-Ray inspection. The below images would lead the viewer to think there was no wire bonding between the Die and the Pins. Despite the X-Ray images not showing this evidence, wire bonding and the die was discovered when the component was de-capped.
X-Ray Image of MC14163BCL |
In the next example part number M5M51008BFP-70LLI (Datasheet and Photos) was inspected using an X-Ray. In the below image it is evident that Pin 1 is a non-connect pin which is consistant with the manufacturers datasheet.
X-Ray Image M5M51008BFP-70LLI |
Oxygen Electronics LLC uses a Nicolet NXR1525 X-Ray in an ANSI ESD S20.20 environment.
Nicolet NXR1525 |
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.